Fire Alarm Systems
[PEGAsys]
[Analaser]
[Alarmline]
[Smoke
Detectors] [Spark
Detection] [Water
Detection] [Vesda
Early Warning Smoke Detection] [Edwards Systems
Technology]
T
& S currently sells, services and installs state-of-the-art fire alarm
systems consisting of, but not limited to, KIDDE/Fenwal, Ansul, Firelite,
EST and Ademco. Specifically, intelligent addressable and zoned hard wired
systems.
T
& S's technicians have been factory trained to give our customers
the best possible system/product and the expertise to service and maintain
the systems.
Listed
below are a few of the many panels and systems we offer.
PEGAsys
Intelligent Suppression
Control System
| Features |
|
- INTELLIGENT SUPPRESSION CONTROL
PANEL
- DISTRIBUTED INTELLIGENCE ARCHITECTURE
- UP TO 255 ADDRESSABLE DEVICES
ON A SYSTEM
- FULL ANALOG REPORTING FROM
SMOKE AND HEAT DETECTORS
- TOTALLY AND EASILY FIELD PROGRAMMABLE
- OPTIONAL ALARM VERIFICATION
- PASSWORD PROTECTED SOFTWARE
|
- 80 CHARACTER ALPHANUMERIC
DISPLAY
- 500+ EVENT HISTORY BUFFER
- WINDOWS BASED PCS PROGRAM
- OPTIONAL OUTPUT MODULES FOR
AUDIBLE / VISUAL SIGNALS, MUNICIPAL TIE, SUPPRESSION AGENT RELEASE,
CONTROL RELAYS
- WALK TEST FUNCTION
- FAILSOFT FEATURE (DEFAULT
OPERATION)
|
| Description |
|
| The KIDDE
PEGAsys is a microprocessor based
Fire suppression control system designed for use with the exclusive
SmartOne series of Intelligent detectors
and Loop Devices. The PEGAsys system operates
within a unique "Distributed Intelligence" architecture
which as it sounds, distributes the processing power throughout
all system components. This "Smart" architecture which
has a microprocessor, memory and software in each system component
brings major increases in system precision and reliability when
compared to other fire alarm system architectures.
The KIDDE PEGAsys
features the exclusive BIP (Broadcast Indexing Protocol)
for loop device communications which has a high immunity to EMI
and RFI. As a result, up to 255 SmartOne Intelligent
loop devices can be connected to the single, two wire communication
loop. Because the loop controller supervises each smart device
through communication with each individual device, the field wiring
can be "T" tapped or branched as often as sound installation
techniques allow. The BIP protocol is so robust that in retrofit
installations the existing detection loop wiring can be reused
thus reducing system installation costs.
ALL OF THE 255 ADDRESSABLE
INPUT / OUTPUT DEVICES CAN BE IN ALARM AND OPERATED AT THE SAME
TIME. Because of this critical feature, even a fire event
which involves a large number of detectors can be reported and
logged by the system.
|

 |
| |
|

ANALASER
Air Sampling
Smoke Detection
| Advanced
Technology High-Sensitivity Smoke Detection Is Essential: |
|
- WHERE EARLY WARNING
IS CRITICAL TO PROTECT HIGH VALUE ASSETS
|
- Telecommunications
- Computer Rooms
- Anechoic Chambers
- Museums
- Electronic Manufacturing
Today's sophisticated telecommunications,
computer, and business systems are so vital that even a minor
interruption in their operation, or loss of data, could create
serious or even crippling financial losses or life safety dangers.
The electronic hardware found in such installations is highly
vulnerable to fire and can be seriously affected by increases
in temperature of contamination from smoke or corrosive gasses.
In these and other areas such as museums, electronic manufacturing
facilities, or anechoic chambers where high-value property is
present, AnaLASER Advanced Technology Smoke Detection provides
the early warning that can spell the difference between a minor
inconvenience and a major catastrophe.
|
- WHERE CONVENTIONAL
DETECTORS WON'T WORK PROPERLY
|
- Clean Rooms
- Atriums
- High-Bay Warehouses
- Nuclear Facilities
- Correctional Facilities
In order for a smoke detector to
work properly, smoke in a concentration sufficient to trigger
an alarm must get to the detector.
In many cases, this may take so
long and involve a fire of such magnitude that conventional
detectors are virtually useless. High-bay warehouses, where
detectors are physically far removed from sources of combustion,
clean rooms with laminar airflow and rapid air changes that
dilute smoke, atriums, and other areas where conventional detectors
may be rendered inoperable by damage or vandalism, require the
high-sensitivity and active air sampling of AnaLASER Advanced
Technology Smoke Detection.
|
| Up
to 1000x more sensitive than conventional Smoke Detectors |

Alarmline
Linear Heat
Detection System
|